Technical data
Application pedestrian crossings
Assembly A - for mounting on a column with a diameter of ø60; B - universal handle for mounting on a column with a diameter of ø76-100
Ingress protection IP 65
Material
Operating temperature range from -30°C to +55°C
Battery type
Communication Wireless communication 2,4 GHz, range to 300 m
Programmable activation time of the flashing light
Dimensions
Battery energy storage
Maximum electric power
Built-in battery charging power
icon eco.svgicon CE.svgicon class II (2).svgIP65.svgAC-220-240.svgicon AI.svgANODA.svg

SYSTEM DESCRIPTION

The signaling lamp is designed to be installed at pedestrian crossings. The blinking lamp warns vehicle drivers about the presence of pedestrians in the crossing. Activation can take place via a button installed on the column, or by means of a motion sensor detecting the presence of pedestrians. All lamps assigned to the same group, i.e. located on the same doorway, are switched on. Control within one passage is carried out based on wireless communication - thus eliminating the need to connect the systems on different sides of the road with control wires. Thanks to the use of a buffer power supply system with a battery energy storage, the system works around the clock also in circuits where the power is disconnected during the day - the buffer power supply system at night collects energy that is used during the day. 

SYSTEM OPERATING MODES

Night mode

The Safe Crosswalk Lighting System is powered from the AC network. Activating the button by a pedestrian turns on the warning lamps for a specified period of time and increases the lighting power of street luminaires equipped with the "Line Switch" function. In night mode, the battery is charged and powers the system in day mode

Day mode

The AC power source is turned off. The Safe Crosswalk Lighting System is powered by a rechargeable battery. Activating the button by a pedestrian turns on the warning lamps for a specified period of time. The power buffer circuit becomes disconnected when the packet voltage reaches the configured trip threshold.

Comparison of pedestrian crossings before and after modernization.

In a typical version of the product, the cable lengths are as follows: power cord 5m; signal cable for pedestrian button 5 m; 2.5m lamp power cord. The standard lengths allow the system to be mounted on the SAL DL -10 pole. If it is necessary to use cables of a different length, please contact the Sales Department of the ROSA company.

The mounting element of the set is the A or B handle
(depending on the type of column):

Handle A
a handle for mounting on a column with a diameter of 60 using screws ST6,3x19 (recommended installation on the SAL DL-10 column)

Handle B
universal handle for mounting on a column with a diameter of ø76-100 with the use of clamps